Several workplace exposure limit changes relevant to food processing take effect on 1 December 2026, as outlined in Safe Work Australia’s changes to workplace exposure limits. Of the six substances covered here, three gain limits for the first time, two have tighter limits, and one relates to diesel-powered equipment used on site.
Knowing what’s changing is one thing. Understanding whether existing controls are enough is another. A strong food hygiene record doesn’t necessarily mean airborne exposure risks are being adequately managed..Â
Overview.
- Flour dust, diacetyl and peracetic acid gain limits for the first time.Â
- Grain dust and sulfur dioxide tighten, and diesel particulate gains a first limit.Â
- Three measurement types apply, and treating them all as shift averages misreads the data.Â
- Hygiene ventilation and exposure control answer different questions about the same air.Â
- The usual shortfall is capture geometry, not fan capacity.Â

What changes, and where it comes from.Â
| Substance | Old limit | New limit | Generated by |
| Flour (cereal) dust | Generic dust only | 0.5 mg/m³ | Mixing, milling, sieving, tipping |
| Diacetyl | None | TWA 0.01 ppm, STEL 0.02 ppm | Butter flavourings |
| Peracetic acid | None | 0.4 ppm peak limit | Sanitising |
| Grain dust | 4 mg/m³ | 1.5 mg/m³ | Milling, handling, silos |
| Sulfur dioxide | 2 ppm | 0.25 ppm | Preservatives, fermentation |
| Diesel particulate | None | 0.01 mg/m³ | Forklifts and plant running indoors |
Flour is the headline change because it had no dedicated limit before, sitting under the generic inhalable dust provision instead. The new figure is substantially stricter than what most bakeries and ingredient plants have been measuring against.Â
Clean for the product isn’t clean for the worker. Â
Food plants are ventilated with contamination in mind. Air curtains hold separation between zones, filtered supply keeps incoming air clean, extraction clears steam before it condenses on product. That reasoning is sound and it answers a different question.
Contamination control asks whether airborne material reaches the product. Exposure limits ask whether it reaches the worker. A plant can hold a spotless hygiene record while having never measured what an operator breathes across a shift of bag tipping.
Dust and vapour also behave differently, which is why one system rarely covers both:
- Dust settles. Flour and grain come from identifiable points, heavy enough to drop out of the air and be re-suspended later by housekeeping or air movement.
- Vapour disperses. Diacetyl, peracetic acid and sulfur dioxide spread rather than settle, and don’t respond to capture geometry designed for dust.
- Filters only catch one. A particle filter does nothing to a vapour.
Fanquip covers the range of requirements across a site in what determines the right ventilation approach for food processing.
How each limit is measured decides what counts as compliant.
Three measurement types appear across these six, and a site treating them all the same way will read its own data wrongly.
| Type | What it means | Applies to |
| Eight-hour TWA | Maximum average across a full shift | Flour dust, grain dust, sulfur dioxide, diesel particulate |
| STEL | 15-minute average, catching short spikes | Diacetyl, alongside its TWA |
| Peak limit | Ceiling never to be exceeded, not averaged | Peracetic acid |
Wash-down shows the difference most clearly. A crew using peracetic acid for twenty minutes could sit comfortably under any shift average and still breach a peak limit, because a peak limit isn’t averaged at all.
Old monitoring data still has a job to do.Â
Nothing on the production floor has to change for a compliant plant to find itself non-compliant, which makes the last hygiene survey the cheapest place to start.
- Re-read it against the new values, not the ones it was measured against.Â
- Check the fraction. Several substances now split into inhalable and respirable limits, and respirable is the harder test.Â
- Check what wasn’t measured. Diesel particulate and peracetic acid are new, so most reports won’t cover them at all.Â
Where monitoring comes back high, the question moves from sampling to controls, and that’s where the ventilation work starts.

A full redesign usually isn’t the answer.Â
The instinct is to replace the whole extraction system. For most plants that’s an overreaction:
- Scope: a plant-wide redesign needs the production line modelled around it.Â
- Disruption: the works compete with production schedules.Â
- Timing: capital approval rarely clears inside a fixed regulatory window.Â
The cheaper lever is geometry, not hardware. Capture velocity, hood design and duct sizing all follow from the concentration the system has to hold, so anything specified before 2026 was solving for a different number. More often that means a hood in the wrong place than a fan that’s too small, and it can be fixed station by station. Ventilation design considerations for the food processing industry covers the inputs that drive it.Â
Where the equipment sits.Â
- Capture at the point of generation. Mobile fume extractors capture at the station and move with the work, which suits plants where the layout changes between runs.Â
- Extraction at ceiling level. Vertical discharge roof fans clear what escapes capture, with upward discharge that prevents recirculation back into the building.Â
- Replacement air that doesn’t bring contamination with it. Extraction only performs to its rating when air can enter. Filtered roof supply fans deliver clean make-up air through the roof, which suits plants where ceiling cavities leave no room for filter boxes.Â
All three are washdown-ready where the environment needs it. The full range sits under Fanquip’s food processing and production.

Where to start.
Fanquip’s guide covers every category of change, the full list of new substances, an industry-by-industry breakdown including food and beverage, and a readiness plan with old and new values side by side. Download The 2026 Workplace Exposure Limit Changes.
For a read on a specific plant, talk to Fanquip’s team before the December run begins.
FAQs
Flour dust at 0.5 mg/m³, diacetyl at 0.01 ppm and peracetic acid at 0.4 ppm are new. Grain dust drops to 1.5 mg/m³ and sulfur dioxide to 0.25 ppm. Diesel particulate gains a first limit at 0.01 mg/m³ where plant runs indoors.Â
Not necessarily. Contamination control asks whether airborne material reaches the product; exposure limits ask whether it reaches the worker. The same system may answer one and not the other.Â
It carries a peak limit rather than an eight-hour average, meaning a ceiling that must never be exceeded even briefly. Short, intense exposure during wash-down can breach it without affecting any shift average.
Â
It applies anywhere diesel plant runs indoors or semi-enclosed, which usually means forklift traffic through dispatch, movement in and out of cold storage, and idling at loading docks.
Yes, read against the new values. Check the fraction measured as well as the number, since several substances now carry separate inhalable and respirable limits.Â
Usually not. A hood in the wrong place is more often the problem than fan capacity, and that can be fixed station by station rather than as a single plant-wide project.Â