Reducing ammonia in a livestock shed starts with litter moisture. 

Reducing ammonia in a livestock shed starts with litter moisture. 

Share Article

Ammonia in a poultry shed is largely a symptom rather than a cause. AgriFutures’ best practice litter management manual puts it directly: while ammonia is an issue in meat chicken production, it is a symptom of other factors, particularly moisture levels. Moisture is also the factor a ventilation system can act on, which makes it the practical place to start.

Overview. 

  • Ammonia follows moisture: litter moisture content is among the main drivers of ammonia production. 
  • 20 ppm is the poultry target: with some farming schemes requiring lower. 
  • Evaporation needs four things: surface moisture, warm litter, air that can absorb it, and air speed at the litter. 
  • Exhaust alone has limits: air speed at litter level is hard to achieve outside tunnel ventilation mode. 
  • Circulation and extraction pair up: one moves air across the litter, the other takes the moisture out. 

Moisture is the factor ventilation can act on.

The factors that increase ammonia production are pH, temperature, moisture content, bedding type, chicken age, manure age, relative humidity and ventilation rate. 

The production system sets several of those and can’t be adjusted mid-batch. Moisture content, relative humidity and ventilation rate are the three that respond to how a shed is ventilated, and they’re connected: moisture leaves the litter by evaporation, and evaporation depends on the condition and movement of the air above it. A shed that can’t remove moisture ends up with wet litter, and ammonia is generated in the litter. 

Evaporation needs four conditions, not one.

Water leaves the litter only when four conditions are present:

  • Moisture at the litter surface. Trapped moisture below the surface doesn’t evaporate, which is why litter conditioning matters.
  • Warm litter. Cool litter alongside warm, humid in-shed air contributes to wet litter rather than drying it.
  • Air that can absorb moisture. In-shed relative humidity below 60%, which means preserving or adding heat, or increasing the ventilation rate to bring in drier air. The air that matters is the air in contact with the litter, so conditioning incoming air before it reaches the floor affects how much moisture it can pick up.
  • Air speed at the litter surface. Moving air carries moisture away from where it sits.

Ventilation sits across three of the four. The fourth comes from litter management.

The last one is also where the constraint most often missed shows up. It is difficult to increase air speed at the litter surface using exhaust fans unless the shed can be operated in tunnel ventilation mode. In tunnel mode the shed moves air lengthwise at speed, which does reach the litter. Outside that configuration, extraction handles the air exchange. It doesn’t necessarily move air across the litter itself, which is why most sheds need both.

Where the ammonia threshold sits. 

Poultry management guidance puts the in-shed ceiling at 20 ppm, with some farming schemes requiring lower to meet their minimum standards. That figure is a meat chicken target rather than a universal livestock limit. Workplace exposure limits for people sit under separate rules.

The recommended response is direct: increase ventilation rates if ammonia and wet litter become problems. Where ventilation alone can’t bring concentrations down, litter additives are a secondary measure rather than a substitute for best management practice. 

What works in a shed

Air movement at litter level. Air circulators move air across the shed floor where evaporation happens. Fanquip supplied 80 utility air circulators to a poultry operation. The 800mm units run at 960rpm, moving 5,115 l/s each, with galvanised shells and IP56 rating for shed conditions.

Extraction at volume. Wall fans mount through the shed wall, with end wall units using the full structural width to move the air volumes a large shed needs. Agricultural installations need corrosion-resistant construction given the ammonia and moisture exposure, which choosing wall exhaust fans covers in detail.

Roof-level extraction. Roof fans remove heat and humid air where it accumulates, which suits sheds not configured for tunnel ventilation.

Fanquip’s work reducing heat build-up across dual dairy sheds started from the same place. Limited natural airflow across two open-walled sheds drove heat build-up through the warmer months. Fanquip supplied a tailored air movement solution across both.The driver there was heat rather than ammonia, and an open-walled shed ventilates differently to an enclosed one. What carries across is the mechanism: still air holds heat and moisture where they are, and moving air takes both away.

The full range sits under Fanquip’s agriculture solutions.

Ammonia control is a moisture balance. 

A shed accumulating ammonia is usually a shed gaining more moisture than it removes. That makes the useful questions mechanical rather than chemical: how much moisture is going in, how much is leaving, and whether air is moving where the evaporation needs to happen.

Managing wet litter covers the litter side of that balance in full. The ventilation side depends on shed design, stocking density and what’s already installed. That’s harder to work out from a guide. Where the litter management is right and the shed still isn’t drying, the answer usually sits in the airflow, and Fanquip’s team can work through that for a specific shed.

FAQs 

How do you reduce ammonia and moisture in a livestock shed? 

Control litter moisture, since ammonia production largely follows it. That means ventilation removing humid air, replacement air dry enough to absorb more moisture, and air movement at litter level where evaporation happens. 

What ammonia level is too high in a poultry shed?

The accepted ceiling in meat chicken production is 20 ppm in-shed, with some farming schemes requiring lower to meet their minimum standards.

Why does wet litter cause ammonia?

Ammonia is generated in the litter, and moisture content is among the factors that increase production, alongside pH, temperature, bedding type, bird age, manure age, relative humidity and ventilation rate.
 

Do exhaust fans alone control ammonia? 

Not entirely. Exhaust handles air exchange, but it is difficult to increase air speed at the litter surface using exhaust fans unless the shed runs in tunnel ventilation mode, so circulation is usually needed alongside it. 

What relative humidity should a shed hold? 

Below 60% in-shed relative humidity, achieved by preserving or adding heat, or increasing the ventilation rate to introduce more fresh, dry air.

Does this apply to dairy and piggery sheds? 

The underlying relationship between moisture and ammonia holds across livestock housing, but litter management in a meat chicken shed is specific to that system. Dairy and piggery housing use different flooring, manure handling and ventilation design, so the thresholds and the approach differ. 

Stay up to date

Stay up to date with the latest sales, service tips and news. Discover the complete Fanquip product range via our catalogue, with industrial cooling, heating, filtration, and ventilation solutions across a wide range of industries. Refer to our industrial guides for insights into common ventilation issues and solutions provided by Fanquip.